Part Number Hot Search : 
AT88SC X8566L TSA5059A SRD820 2SC2839 R43391 0DC24 S4008DS2
Product Description
Full Text Search
 

To Download MPM-15 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com input parameter conditions min. typ. max. units input voltage range 85 264 vac 120 370 vdc input frequency 47 63 hz input current see model selection guide inrush current 115 vac 10.0 a pk 230 vac 20.0 emi meets cispr pub. 22/fcc class b safety ground leakage current 115 vac 0.1 ma 230 vac 0.3 output parameter conditions min. typ. max. units output voltage see model selection guide output current see model selection guide output voltage accuracy ?.0 % line regulation ?.5 load regulation see model selection guide ripple & noise (20 mhz) 50 mv pk - pk hold-up time 115 vac 20 msec 230 vac 80 temperature coef cient ?.02 %/? short circuit protection continuous (autorecovery) overload protection typ. 110% of output power general parameter conditions min. typ. max. units isolation voltage input to output 3,000 vac input to ground 1,500 output to ground 500 emi/rfi conducted en 55022 level b emc compliance electrostatic discharge (esd) iec/en 61000-4-2 level 3 rf field susceptibility iec/en61000-4-3 electrical fast transients/bursts on mains iec/en 61000-4-4 level 3 2 kv surge iec/en 61000-4-5 level 3 1kv/2 kv switching frequency 150 khz environmental parameter conditions min. typ. max. units operating temperature range ambient -20 +25 +70 ? case +90 ? storage temperature range -25 +105 ? cooling free air convection (see derating curve) humidity rh, non-condensing 85 % physical case size 2.44 x 1.77 x 0.88 inches (62.0 x 45.0 x 22.5 mm) case material non-conductive black plastic (ul94-v0) weight 5.11 oz (145g) reliability speci cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25?, gnd benign 200 khours safety standards ien 60950, iec 60950 safety approvals (pending) ien 60950, iec 60950 compact, 15w pc mount single, dual & triple out ac/dc power supplies key features: 15w output power universal 85-264 vac input en 60950 compliant single, dual & triple outputs meets en55022 b >200 khour mtbf compact pc mount case MPM-15 series rohs compliant electrical speci cations speci cations typical @ +25?, 230 vac input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. www.datasheet.net/ datasheet pdf - http://www..co.kr/
model selection guide mechanical dimensions notes: all dimensions are typical in inches (mm) tolerance x.xx = 0.01 ( 0.25) pin single dual triple 1 no pin ac-ground ac-ground 2 ac-neutral ac-neutral ac-neutral 3 ac-line ac-line ac-line 4 -vo 1 -vo 2 -vo 1 5 no pin no pin +vo 1 6 no pin common -vo 2 7 no pin no pin common 8 +vo 1 +vo 1 +vo 2 pin connections micropower direct www.micropowerdirect.com 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com notes: 1. load regulation is measured for an output change of 10% to 90% at nominal input line. for multiple output models, the loads are balanced. 2. the MPM-15 series is speci ed for operation over the wide operating temperature range of -20? to +55? without derating. for operation over +55?, derate the power linearly by 3.75%/? from +55? to +70?. 3. it is recommended that a fuse be used on the input of a power supply for protection. for the MPM-15 series, a 2a/250 vac slow blow should be used. model number input output 1 (vout 1) output 2 (vout 2) output 3 (vout 3) ef ciency (%, typ) current (a) voltage (vdc) current (a) over volt. protection (vdc) voltage (vdc) current (a) over volt. protection (vdc) voltage (vdc) current (a) 115 vac 230 vac typ. load reg. typ. load reg. typ. load reg. MPM-15s-03 0.25 0.14 3.3 3.000 ?.0% 6.5 80 MPM-15s-05 0.25 0.14 5.0 2.800 ?.0% 6.5 80 MPM-15s-12 0.25 0.14 12.0 1.250 ?.0% 20.0 80 MPM-15s-15 0.25 0.14 15.0 1.000 ?.0% 20.0 80 MPM-15s-24 0.25 0.14 24.0 0.625 ?.0% 30.0 80 MPM-15s-48 0.25 0.14 48.0 0.320 ?.0% 30.0 80 MPM-15d-05 0.25 0.14 +5.0 +1.50 ?.0% 6.5 -5.0 -1.50 ?.0% 6.5 80 MPM-15d-12 0.25 0.14 +12.0 +0.65 ?.0% 20.0 -12.0 -0.65 ?.0% 20.0 80 MPM-15d-15 0.25 0.14 +15.0 +0.50 ?.0% 20.0 -15.0 -0.50 ?.0% 20.0 80 MPM-15t-0505 0.25 0.14 5.0 2.60 ?.0% 6.5 +5.0 +0.20 ?.0% -5.0 -0.20 ?.0% 80 MPM-15t-0512 0.25 0.14 5.0 2.00 ?.0% 6.5 +12.0 +0.20 ?.0% -12.0 -0.20 ?.0% 80 MPM-15t-0515 0.25 0.14 5.0 1.80 ?.0% 6.5 +15.0 +0.20 ?.0% -15.0 -0.20 ?.0% 80 MPM-15t-0524 0.25 0.14 5.0 2.00 ?.0% 6.5 +24.0 +0.10 ?.0% -24.0 -0.10 ?.0% 80 typical connection vout c1, c3, c5 c2, c4, c6 fuse tvs 3.3 330 ~ 1,000 f/16v 0.1 f/50v ceramic 2a/ 250 vac slow blow p6ke6.8a 5.0 330 ~ 1,000 f/16v p6ke6.8a 12.0 220 f/25v p6ke16a 15.0 220 f/25v p6ke20a 24.0 120 f/35v p6ke33a 48.0 68 f/63v p6ke62a typical component values notes: 1. c1, c3 and c5 are high frequency, low resistance electrolytic capacitors. refer to the suppliers speci cations for capacitance/current ratings. 2. voltage derating on all capacitors should be 80% or higher. 3. c2, c4 and c6 eliminate high frequency noise. 4. the tvs is recommended to protect load circuitry in the event of a module failure. www.datasheet.net/ datasheet pdf - http://www..co.kr/


▲Up To Search▲   

 
Price & Availability of MPM-15

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X